HI 8633 and HI 8733 Multi-Range Conductivity Meters for Laboratory Use
The HI 8633 and HI 8733 have been designed specifically for use in the areas of production and quality control. It is often necessary to test samples with different concentrations ranging from deionized water to brine. The amperometric system would require constant recalibration and probe changes, thus making the measurement process very time consuming and unreliable. To solve this problem, the HI 8633 uses a 4-Ring potentiometric probe. The rugged probes made in PVC are ideal for indoor as well as outdoor measurements.
By using one point calibration, it is now possible to obtain accurate readings across a very wide range from 0.1 to 199900 µS/cm.
If the temperature of the solution fluctuates, the HI 8733 with a built-in temperature sensor and Automatic Temperature Compensation is the perfect instrument.
As an accessory, the HI 721313 is available. The kit includes a rugged carrying case with a beaker, a calibration screwdriver and standardizing solution at 12880 µS/cm.
Features and Benefits
- 4-Ring potentiometric probe for wide measurement range
- Rugged PVC probes ideal for indoor and outdoor measurements
- One point calibration for accurate readings from 0.1 to 199900 µS/cm
- Manual or Automatic Temperature Compensation available
- Single point calibration through trimmer
- Interchangeable probes with screened cable option
Specifications
| Parameter |
HI 8633 |
HI 8733 |
| Ranges |
0.0 to 199.9 µS/cm 0 to 1999 µS/cm 0.00 to 19.99 mS/cm 0.0 to 199.9 mS/cm |
0.0 to 199.9 µS/cm 0 to 1999 µS/cm 0.00 to 19.99 mS/cm 0.0 to 199.9 mS/cm |
| Resolution |
0.1 µS/cm 1 µS/cm 0.01 mS/cm 0.1 mS/cm |
0.1 µS/cm 1 µS/cm 0.01 mS/cm 0.1 mS/cm |
| Accuracy (@20°C/68°F) |
±1% Full Scale (excluding probe error) |
±1% Full Scale (excluding probe error) |
| Typical EMC Deviation |
±2% Full Scale |
±2% Full Scale |
| Calibration |
Manual single point through trimmer |
Manual single point through trimmer |
| Temperature Compensation |
Manual from 10 to 40°C (50 to 104°F) with ß of 2% per degree °C |
Automatic from 0 to 50°C (32 to 122°F) with an adjustable ß from 0 to 2.5% per degree °C |
| Probe |
HI 76301W with 1 m (3.3') cable (included) |
HI 7633W with ATC, 1 m (3.3') screened cable (included) |
| Battery Type / Life |
1 x 9V / approximately 100 hours of continuous use |
1 x 9V / approximately 100 hours of continuous use |
| Environment |
0 to 50°C (32 to 122°F); RH 95% |
0 to 50°C (32 to 122°F); RH 95% |
| Dimensions |
185 x 82 x 45 mm (7.3 x 3.2 x 1.8") |
185 x 82 x 45 mm (7.3 x 3.2 x 1.8") |
| Weight |
355 g (13 oz.) |
355 g (13 oz.) |
Ordering Information
HI 8633 is supplied complete with HI 76301W interchangeable conductivity probe with 1 m (3.3') cable, calibration screwdriver, 9V battery and instruction manual.
HI 8733 is supplied complete with HI 7633W interchangeable conductivity probe with 1 m (3.3') screened cable, calibration screwdriver, 9V battery and instruction manual.
Accessories
- HI 76301W - Conductivity probe for HI 8633
- HI 7633W - ATC conductivity probe for HI 8733
- HI 710001 - Soft carrying case
- HI 721313 - Rugged carrying case
- HI 710009 - Blue rubber boot
- HI 710010 - Orange rubber boot
- HI 7030L - 12880 µS/cm calibration solution (460 mL)
- HI 7031L - 1413 µS/cm calibration solution (460 mL)
- HI 7033L - 84 µS/cm calibration solution (460 mL)
- HI 7034L - 80000 µS/cm calibration solution (460 mL)
- HI 7035L - 111800 µS/cm calibration solution (460 mL)