Upright Ultralow Freezer
21cu.ft., touch screen ultra-low temperature freezer.
Protect your samples with steel-insulated inner doors for ultimate
temperature retention down to -86°C. Experience highly efficient variable speed
compressors for energy savings and enhanced system performance. Conduct
advanced data logging through intuitive touchscreen control—track real-time
temperature readings, export data, and capture trends with just a few taps. Dual
voltage compatibility ensures installation flexibility, with each unit including
both 115V and 230V power cords under a single part number. You can also rest
secure knowing your samples are guarded by a full array of alarms—no more
surprise temperature excursions. As a finishing touch, you’ll benefit from natural
hydrocarbon refrigerants for sustainability, energy efficiency, and long-term cost
savings. Together, these features are designed to push boundaries and harness
the full potential of the modern ULT.
SPECIFICATIONS:
Storage capacity (cu. ft): 21 Cu. Ft. Capacity
Door: One solid exterior door, right hinged, not reversible; Five insulated inner doors
Shelves: Four adjustable, stainless steel (standard), tested to 160 lbs. (optional configurations available)
Box Capacity Qty. 400 2″ boxes (25 UF442 racks)
Mounting: Four heavy duty swivel casters with locks
External probe access: 1/2″ diameter port; access from back of unit to interior left side
Insulation: Foamed-in-place EPA compliant high density urethane foam
Exterior materials: Powder coated Steel
Insulation: Cabinet is foamed-in-place with EPA compliant high density urethane foam
Interior lighting: Non-applicable
Access Control: Keyed lock on exterior door handle
General warranty: Five (5) year parts and labor warranty
Compressor warranty: Seven (7) years compressor warranty
Exterior (in): 43.3″w x 36.3″D x 79.6"H
Rated Amperage 10A (120V), 6A (240V)
Power Plug/Power Cord: Two detachable cords supplied, min. 8′ length: 120V (NEMA 5-15 Plug) and 240V (NEMA 6-15 Plug)
Facility Electrical Requirement: Dual Voltage 110-120V 15A (minimum) or 208-240V AC 15A (minimum)
Agency Listing and Certification: UL/C-UL listed. Certified to UL 60335-2-89 Safety Standard
Vacuum Relief Port: Includes heated vacuum relief port for pressure equalization reducing wait times between door openings
Average heat rejection (BTU/h): 1627 BTU/h
Energy Consumption (kWh/Day/CUFT) As low as 0.48 kWh/day/cu.ft.
Adjustable Temperature Range: -86°C to -50°C
Warm-up times: 180+ minutes -80°C to -50°C°
Refrigerant: R290 / R170
Energy Consumption (KWh/day): As low as 0.48 kWh/day/cu.ft.
Evaporator: Cold wall (Natural convection)
Compressor: Two ea. variable speed hermetic reciprocating
Condenser: Tube and Fin design, EC fan, easy clean removable filter
Controller technology: Microprocessor with color touchscreen (11in) input and display, C° or F°
Battery Backup: 12V high capacity battery for controller and touchscreen display: temperature monitoring, alarms, and event logging active
External alarm connection: State switching remote alarm contacts
Digital Communication: 4-20mA output for temperature monitoring
Alarms: Audible and Visual Alarms: customizable sounds and volumes; mute with visual persistence; ring-back functionality re-engages audible alarm after pre-set delay if alarm condition persists. Adjustable delays for door, temperature, power loss.
| Stock Number | N2434 |
| Model | 21 cu-ft (-86C) |
| Manufacturer | ABS |
| Product Brochure | |
| Warranty | 2 YEAR MANUFACTURER'S WARRANTY ON PARTS AND LABOR, 7 YEAR COMPRESSOR PARTS WARRANTY |