Closed Cup Flash Point Tester

Made in United States
Ships from United States
https://www.labequip.com/web/image/product.template/33751/image_1920?unique=663336a

The Koehler K87760 tag tester offers simple automation routine for easy operation. For determining flash point through an Automatic Tag Closed Cup Tester, conforming to ASTM D56. Used for flash point determinations of liquids with a viscosity below 5.5 mm2/s (cSt) at 40 °C (104 °F), or below 9.5 mm2/s (cSt) at 25 °C (77 °F), and a flash point below 93 °C (200 °F), except for cutback asphalts which tend to form a surface film under test conditions and materials which contain suspended solids..

• Integrated wireless temperature sensor and thermocouple detection
• Selectable gas or electronic ignition; built-in safety logic and automatic error messages.
• Built-in Peltier cooling system; external cooling bath optional for extended low-temperature capability
• Integrated Thermal Printer and Large-Capacity Data Storage

The Automatic Tag Flash Point Tester is a bench-top, fully-automatic Tag Closed-Cup flash point tester that combines high-accuracy temperature sensing, selectable ignition modes (gas or electronic), automatic detection and safety interlocks, built-in cooling (Peltier) with optional external refrigeration bath for low-temperature determinations, and data storage/communication for traceable records. Designed to meet the precision and procedure requirements of ASTM D56 and comparable standards.

SPECIFICATIONS:
- Conforms to the Specifications of: ASTM D56, D3941, D3934; ISO 1516, 1523; GB/T 21929, 21775
- Measurement Range: 10°C to 130°C (with internal refrigeration)
-30°C to 130°C (with external refrigeration)
- Temperature Sensor: Integrated wireless temperature sensor
- Sensor Resolution: 0.1 °C
- Measurement Accuracy: ±0.1 °C
- Ignition Method: Selectable between gas and electronic
- Flash Fire Detection Method: Thermocouple detection
- Data Record Storage: 2000 Groups
- Cooling Method: Built-in Peltier cooling system (external cooling bath optional)
- Minimum Cooling Temperature: -35°C (requires external cooling bath)
- Blind Sample Test: Supports unknown sample pretest
- Alarm/Prompt Function: Audible beep at the end of the test; automatic error message display
- Data Output: Built-in micro thermal printer; results transferable to LIMS
- Communication Interface: RJ45 Ethernet, RS232

Installation and training on site is mandatory and is additional cost.

30,999.00 30999.0 USD 30,999.00

1.00

Not Available For Sale

This combination does not exist.

Petroleum Testing

Terms and Conditions



Stock Number N1302
Model K87760 Tag
Manufacturer Koehler Instrument
Standard Test Methods ASTM D56
Product Brochure
Warranty 1 YEAR MANUFACTURER'S WARRANTY