Pro Bench Vertical Sash Fume Hood
This general purpose fume hood is designed to meet most laboratory Constant Air Volume (CAV) or Variable Air Volume (VAV) requirements and supplied with an automatic compensating upper by-pass. For VAV, use option S2 for a restricted by-pass plate. Designed to mount on a 30" deep counter top.
Standard Features
- Counterbalance Systems - Chain and sprocket system delivers the easiest and most reliable sash operation available with an exceptionally long life span. High quality stainless steel cable system provides economical and reliable operation; tested to 100,000 cycles with no failure.
- Stainless Steel Airfoil - Aerodynamic raised design allows air to enter the fume hood even when the sash is closed ensuring efficient fume exhaust. Notches in both corners allow electrical wiring or tubing into the fume hood while still permitting full closure of the sash.
- Sash Design - 6mm laminated safety glass is provided with a stainless steel handle and side runners, optional tempered glass or polycarbonate available for special applications. Hood has a vertical sash. 30" viewing height.
- Stainless Steel Type 316 Exhaust Collar - Round collar with radiused corners allows for direct connection to exhaust duct to reduce duct transition costs, minimize static pressure losses and exhaust noise levels.
- Electrical - Two UL/CSA approved duplex receptacles provided for 120 volt service, one on each corner post. UL/CSA approved fluorescent light fixture and switch provided. T5 fluorescent or LED lighting are available options.
- Plumbing - Both corner posts are pre-punched to accept a maximum of five plumbing fittings per post. Factory pre-plumbing is available as well as plumbing fixtures from a variety of manufacturers to meet most plumbing needs.
- Access Panels - Interior gasketed access panels provide convenient access and prevent fume leakage outside the hood chamber. Exterior side panels are also removable for ease of access to plumbing and electrical service fixtures.
- Agency Approvals - UL 1805 Classified, CSA certified to UL 61010 and tested in accordance with ASHRAE 110. Test results available upon request.
Interior Lining Materials
| Material |
Properties |
| FRP (Fiberglass Reinforced Polyester) |
- Resistant to solvents and bases
- Subject to attack by some acids
- Recommended for radioisotope and perchloric acid applications
- High tolerance to flame and heat
- Excellent structural strength
- Excellent cleaning characteristics
- White color
|
| Poly Vinyl Chloride (PVC) |
- Good resistance to most solvents, bases and acids
- Low flame spread rating
- Strong structural strength
- White color
|
| Epoxy Resin |
- Excellent resistance to bases and acids
- Poor tolerance to flame and heat
- Strong structural strength
- Off white color
|
| 316 Stainless Steel Rounded Corners |
- Excellent resistance to solvents, bases and acids
- Moderate tolerance to flame and heat
- Moderate structure strength
|
Model Numbers - Vertical Raising Sash (Cable Sash System)
| Width |
FRP |
PVC |
Epoxy |
316 S/S Sq. Cor |
316 S/S Rad. Cor |
| 36" |
7121000 |
7123000 |
7126000 |
7124000 |
7125000 |
| 48" |
7221000 |
7223000 |
7226000 |
7224000 |
7225000 |
| 60" |
7321000 |
7323000 |
7326000 |
7324000 |
7325000 |
| 72" |
7421000 |
7423000 |
7426000 |
7424000 |
7425000 |
| 96" |
7521000 |
7523000 |
7526000 |
7524000 |
7525000 |
| 1000mm |
7B21000 |
7B23000 |
7B26000 |
7B24000 |
7B25000 |
| 1513mm |
7C21000 |
7C23000 |
7C26000 |
7C24000 |
7C25000 |
| 2000mm |
7D21000 |
7D23000 |
7D26000 |
7D24000 |
7D25000 |
Model Numbers - Vertical Raising Sash (Chain & Sprocket Sash System)
| Width |
FRP |
PVC |
Epoxy |
316 S/S Sq. Cor |
316 S/S Rad. Cor |
| 36" |
7121040 |
7123040 |
7126040 |
7124040 |
7125040 |
| 48" |
7221040 |
7223040 |
7226040 |
7224040 |
7225040 |
| 60" |
7321040 |
7323040 |
7326040 |
7324040 |
7325040 |
| 72" |
7421040 |
7423040 |
7426040 |
7424040 |
7425040 |
| 96" |
7521040 |
7523040 |
7526040 |
7524040 |
7525040 |
| 1000mm |
7B21040 |
7B23040 |
7B26040 |
7B24040 |
7B25040 |
| 1513mm |
7C21040 |
7C23040 |
7C26040 |
7C24040 |
7C25040 |
| 2000mm |
7D21040 |
7D23040 |
7D26040 |
7D24040 |
7D25040 |
Exhaust Parameters
| Hood Size |
Duct Dia. |
100 FPM 18" Max Sash Opening CFM |
100 FPM 18" Max Sash Opening SP |
100 FPM 28-1/2" Max Sash Opening CFM |
100 FPM 28-1/2" Max Sash Opening SP |
80 FPM 18" Max Sash Opening CFM |
80 FPM 18" Max Sash Opening SP |
80 FPM 28-1/2" Max Sash Opening CFM |
80 FPM 28-1/2" Max Sash Opening SP |
| 36" |
10" |
350 |
0.04 |
543 |
0.10 |
280 |
0.03 |
434 |
0.05 |
| 48" |
10" |
508 |
0.09 |
789 |
0.20 |
407 |
0.06 |
630 |
0.15 |
| 60" |
12" |
667 |
0.07 |
1035 |
0.20 |
533 |
0.05 |
830 |
0.15 |
| 72" |
12" |
825 |
0.11 |
1280 |
0.25 |
660 |
0.07 |
1025 |
0.20 |
| 96" |
2@10" |
1142 |
0.11 |
1772 |
0.25 |
913 |
0.07 |
1418 |
0.20 |
| 1000mm |
10" |
395 |
0.05 |
612 |
0.15 |
316 |
0.04 |
490 |
0.10 |
| 1513mm |
12" |
660 |
0.07 |
1025 |
0.20 |
528 |
0.05 |
820 |
0.15 |
| 2000mm |
12" |
914 |
0.14 |
1419 |
0.30 |
731 |
0.09 |
1135 |
0.20 |
Note: 28-1/2" max sash opening is recommended for set-up and tear down only.
Exhaust Duct Connections
While most fume hood duct connections are round, please note that some fume hood models are designed with a rectangular duct connection to reduce turbulence inside the hood. If needed, an optional duct transition from rectangular to round can be ordered separately.
Exhaust Duct Materials
Particular attention should be paid to the exhaust ducting materials to ensure they are resistant to the chemicals which will be used in the lab. Common materials include: stainless steel, galvanized steel, polypropylene, polyethylene, PVC, and fiberglass reinforced polyester. If the lab work will include extensive use of acids then uncoated galvanized or stainless steel should not be used.
Fume Hood Positioning In The Lab
Fume Hood performance and safety is substantially dependent on the layout of the laboratory and particular attention should be paid to supply air grille location, fume hood location, and escape routes. In general, the laboratory layout and supply air conditions need to ensure that drafts in the area in front of the fume hood are maintained below 1/3 of the fume hood face velocity. In addition, attention should be paid to escape routes keeping in mind that the need to cross in front of a fume hood during an evacuation must be avoided.
Fume Hood Plumbing Fixtures
| Service |
Colour |
Item# |
| AIR |
ORANGE |
WFS1001 |