Starter Water Analysis Portable Meters
OHAUS precision is now available in a line of Starter portable water analysis meters for measuring pH, conductivity, salinity, total dissolved solids (TDS), oxidation reduction potential (ORP) and dissolved oxygen (DO). These portable meters offer convenience, reliability and durability in one compact design.
Standard Features
- Intuitive Software – Intuitive software and a well-organized display work in tandem to make operating the Starter Series a simple and straightforward task
- Compact and Ergonomic Design – Starter portable meters fit comfortably in the palm of your hand. Each meter also comes equipped with a retractable built-in stand that can be used to prop it up on a flat surface
- Reliable Calibration Results – Starter portable meters track the accuracy of the calibration process right on the display, so that you can measure with peace-of-mind, knowing that your results will be highly precise
- IP54 Protection – Shields the meter from damage by water and dust particles
- Easy to Use – Clear, well-organized LCD screen with one touch recall of calibration data and stored information
Starter 400D Dissolved Oxygen Meter
ST400D is a practical, affordable, low-maintenance DO portable meter equipped with optical technology - ideal for applications that require simple yet accurate DO measurements.
- The optical probe requires minimal maintenance – frequent membrane replacement not needed. Also, warm up and stirring of samples when taking measurements is not required
- Equipped with a color LCD display, the ST400D is designed to fit comfortably in the palm of your hands. The automatic/manual endpoints enable easy recall of last calibration data and stored information with one touch
- Simple calibration process offers quick delivery of measurements, and automatic temperature and barometric pressure compensation ensure accurate results
Starter 300 pH Meter
Starter 300 combines portability with precise pH measurement.
- With a meter stand, wrist strap for secure field use and IP54 housing, Starter 300 is durable and prepared for versatile use
- Automatic and manual temperature compensation ensure accurate readings while a 30 measurement library stores data for future reference
- The auto buffer recognition stores calibration data and helps to avoid errors during the calibration process
Starter 300C Conductivity Meter
Starter 300C is the reliable and accurate choice for measurement of conductivity and TDS levels of liquids.
- The 30 item library allows the user to store measurements data, and stored information and calibration data can be easily recalled with one touch
- Auto temperature compensation with adjustable temperature co-efficient for accurate measurements, and 4-pole and 2-pole conductivity probes which offer a large conductivity range that safeguards them from effects of polarization and pollution
- With a simple calibration process and quick delivery of measurement results, Starter 300C is efficient and easy-to-use
Starter 300D Dissolved Oxygen Meter
Starter 300D provides accurate and reliable DO measurement, critical to aquatic life and water quality.
- With a simple calibration process, quick delivery of measurements and automatic temperature compensation, Starter 300D is both easy-to-use and accurate
- The automatic or manual endpoints allow the user to easily recall the last calibration data and stored information with one quick touch
- The galvanic electrode can be used immediately after being powered on without the wait time typically associated with dissolved oxygen meters
Specifications
| Model |
ST400D |
ST300 |
ST300C |
ST300D |
| Measurement Range |
0.0 to 200.0% 0.00 to 20.0 mg/L(ppm) 0 to 50 °C |
0.00 to 14.00 pH –1999 to 1999 mV 0 °C to 100 °C |
0.0 μS/cm to 199.9 mS/cm 0.1 mg/l to 199.9 g/l (TDS) 0 °C to 100 °C |
0.0 to 199.9%; 200 to 400% 0.00 to 19.99; 20.0 to 45.0 mg/L 0.00 to 19.99; 20.0 to 45.0 ppm 0 to 50 °C |
| Measurement Resolution |
0.1% 0.01 mg/L(ppm) 0.1 °C |
0.01 pH 1 mV 0.1°C |
Automatic Range 0.1°C |
0.1%; 1% 0.1 mg/L; 1mg/L 0.01 ppm; 0.1 ppm 0.1 °C |
| Barometric Range |
50.0 to 115.0 kPa |
NA |
NA |
375 to 825 mmHg 500 to 1100 mbar 500 to 1100 hPa |
| Barometric Resolution |
0.1 kPa |
NA |
NA |
1 mmHg 1 mbar 1 hPa |
| Error Limits |
± 0.2 mg/L (<8 mg/L), ± 0.3 mg/L (8 to 20 mg/L); ± 0.3 °C ± 1.5 kPa |
± 0.01 pH ± 1 mV ± 0.5 °C |
± 0.5 % of the Measured Value ± 0.3°C |
± 1% ; ± 0.3 °C |
| Calibration |
1 or 2 points |
3 Points 4 Predefined Buffer Group |
1 Point 4 Predefined Standards |
1 or 2 Points 100% and 0% |
| Memory |
99 Measurements Last Calibration Data |
30 Measurements Last Calibration Data |
30 Measurements Last Calibration Data |
30 Measurements Last Calibration Data |
| Power Supply |
4 x AAA (LR03) Batteries, 12 hrs |
4 AAA > 500 Operating Hours |
4 AAA > 250 Operating Hours |
4 AAA > 250 Operating Hours |
| Size/Weight |
Approximately 90 W × 150 D × 35 H mm / 0.16 kg (Without Batteries) |
Approximately 90 W × 150 D × 35 H mm / 0.18 kg (Without Batteries) |
Approximately 90 W × 150 D × 35 H mm / 0.16 kg (Without Batteries) |
Approximately 90 W × 150 D × 35 H mm / 0.18 kg (Without Batteries) |
| Display |
Liquid Crystal |
Liquid Crystal |
Liquid Crystal |
Liquid Crystal |
| Input |
Mini-DIN |
BNC, Impedance > 10e+12 Ω Cinch, NTC 30 kΩ |
Mini-DIN |
BNC Cinch, NTC 30 kΩ |
| Temperature Compensation |
ATC |
ATC & MTC |
ATC, Linear: 0.00 %/°C…10.00 %/°C Reference Temperature: 20 & 25 °C |
ATC & MTC |
| Salinity Compensation |
0.0 to 40.0 ppt |
NA |
NA |
0.0 to 50.0 ppt |
| IP Protection |
IP54 |
IP54 |
IP54 |
IP54 |
| Housing |
ABS |
ABS |
ABS |
ABS |
Available Packages
Starter 300 pH Meter
| Model |
Description |
| ST300-B |
300 Meter with IP54 Sets, Electrode Clip, Wrist Strap and 4 AAA Batteries (Electrode Not Included) |
| ST300 |
ST300-B, ST320 3-in-1 Plastic Gel pH Electrode, and pH Buffer Powder Sachet |
| ST300-G |
ST300-B, ST320 3-in-1 Plastic Gel pH Electrode, pH Buffer Powder Sachet (4.01, 7.00, 10.01), Portable Bag |
Starter 300C Conductivity Meter
| Model |
Description |
| ST300C-B |
300C Meter, Conductivity Standards 1413 μS/cm and 12.88 mS/cm (20mL bottles), IP54 Sets, Electrode Clip, Wrist Strap, 4 AAA Batteries (Probe Not Included) |
| ST300C |
ST300C-B, with STCON3 4-Pole Conductivity Probe (70 μS/cm-200 mS/cm), 2 Small Bottles of Standard Conductivity Solution - 1413 μS/cm and 12.88 mS/cm, IP54 Sets, Electrode Clip, Wrist Strap, 4 AAA Batteries |
| ST300C-G |
ST300C-B, STCON3 4-Pole Conductivity Probe (70 μS/cm - 200 mS/cm), Portable Bag |
Starter 300D Dissolved Oxygen Meter
| Model |
Description |
| ST300D-B |
300D Meter with IP54 Sets, Electrode Clip, Wrist Strap and 4 AAA Batteries (Probe Not Included) |
| ST300D |
ST300D-B with STDO11 Galvanic DO Probe, and STTEMP30 Temperature Probe |
| ST300D-G |
ST300D-B with STDO11 Galvanic DO Probe, STTEMP30 Temperature Probe, Portable Bag |
Starter 400D Dissolved Oxygen Meter
| Model |
Description |
| ST400D-B |
400D Meter with IP54 Sets, Electrode Clip, Wrist Strap and 4 AAA Batteries (Probe Not Included) |
| ST400D |
ST400D-B with STDO21 Probe |
| ST400D-G |
ST400D-B with STDO21 Optical DO Probe, Portable Bag |
Compliance
- Electromagnetic Compatibility: FCC Part 15 Class A; ICES-003 Class A
Compatible Electrodes and Probes
ST300 Compatible Electrodes
| Model |
Description |
| ST350 |
3 in 1 Refillable pH Electrode, |